{"id":3867,"date":"2026-11-21T00:47:00","date_gmt":"2026-11-20T16:47:00","guid":{"rendered":"http:\/\/www.afrah-kw.com\/blog\/?p=3867"},"modified":"2026-11-21T00:47:00","modified_gmt":"2026-11-20T16:47:00","slug":"what-causes-corrosion-in-open-cooling-towers-4fca-41fcae","status":"publish","type":"post","link":"http:\/\/www.afrah-kw.com\/blog\/2026\/11\/21\/what-causes-corrosion-in-open-cooling-towers-4fca-41fcae\/","title":{"rendered":"What causes corrosion in open cooling towers?"},"content":{"rendered":"<p>If you\u2019ve ever stood next to an open cooling tower on an industrial plant, a school campus, or a manufacturing facility, you might have noticed a faint smell of damp concrete, a gentle drift of mist, and that the metal framework or pipe surfaces around it look just a little rougher, discolored, or marked by small pits. Those are telltale signs of corrosion\u2014the same process that turns a bike left out in the rain into a rusted heap, but on a far larger and more impactful scale for open cooling tower systems. As someone who\u2019s spent 12 years working directly with open cooling towers, first as a field service technician and now as part of a team that supplies these systems, I\u2019ve seen first-hand how corrosion doesn\u2019t just eat away at metal; it can lead to premature equipment failure, unplanned downtime, and costly repairs that could have been avoided with a clear understanding of what causes it. <a href=\"https:\/\/www.hnhzark.com\/open-cooling-tower\/\">Open Cooling Tower<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.hnhzark.com\/uploads\/47871\/small\/cooling-tower-gearbox7821d.jpg\"><\/p>\n<p>Open cooling towers operate on a simple, intuitive principle: they pull warm water from industrial processes, HVAC systems, or power generation equipment into a large, open basin, then force air through that water to evaporate excess heat, cooling the water before it cycles back out. Unlike closed cooling systems, which keep water sealed inside pipes, open towers expose their water to the atmosphere, and that exposure is exactly where corrosion starts. The process isn\u2019t just \u201cwater and metal reacting\u201d\u2014it\u2019s a chain of interconnected factors, each amplifying the others to speed up degradation. Let\u2019s break down the most common causes, the ones that show up time and again in the systems we service and supply, so you can spot them before they turn into big problems.<\/p>\n<p>First, and often the biggest culprit, is the quality of the make-up water used in open cooling towers. All open systems lose water through evaporation, drift, and small leaks\u2014sometimes up to 3% of the total water volume every day. To keep the system operating at the right level, you have to add fresh make-up water, usually from municipal sources, wells, or nearby lakes. That water isn\u2019t pure. It carries a mix of dissolved minerals: calcium, magnesium, and the big ones for corrosion, chloride and sulfate. Chloride is particularly aggressive. It\u2019s small enough to seep through the passive oxide layer that forms on stainless steel or galvanized steel, the thin, protective skin that keeps metal from reacting directly with water. Once chloride breaks through that layer, it attacks the underlying metal, creating small, sharp pits that can weaken a pipe wall in just a few years. I once visited a food processing plant where their make-up water had 300 ppm of chloride\u2014three times the level we recommend for open towers\u2014and within two years, their 6-inch steel supply pipe had corroded through, causing a flood that shut down production for 18 hours. Sulfate works similarly, eating away at concrete and metal alike, and if the water has high total dissolved solids (TDS), that increases the conductivity of the water, making it easier for electrical currents (which drive electrochemical corrosion) to flow between different metal components in the tower.<\/p>\n<p>Then there\u2019s the role of oxygen in the air, which is abundant in open systems. Corrosion in metal is an electrochemical reaction: metal atoms lose electrons to oxygen, forming metal oxides (rust, for galvanized steel) that flake off and weaken the structure. In closed systems, oxygen is usually removed from water before it circulates, but open towers intentionally expose water to air, so oxygen levels stay high. Even worse, the process of splashing and spraying water to create maximum surface area for evaporation adds more oxygen to the mix, supercharging the reaction. For copper components, which are often used in piping or heat exchangers, oxygen combines with water to form copper oxide, which can break down into small particles that clog nozzles and reduce the tower\u2019s efficiency over time. I\u2019ve seen towers where years of high oxygen exposure left copper fill media (the material that increases water surface area) pitted so badly that water flow dropped by 25%, forcing the plant to replace the entire fill a full 5 years ahead of schedule.<\/p>\n<p>Next, biological growth in open cooling towers is a hidden, persistent driver of corrosion. The warm, damp environment of an open tower is perfect for bacteria, algae, and fungi to thrive. Those organisms form slimy biofilms that coat the inside of pipes, the surface of metal frameworks, and the fill media. Biofilms aren\u2019t just an eyesore\u2014they create localized environments where corrosion runs rampant. Here\u2019s how: the thick slime cuts off oxygen to parts of the metal surface, creating tiny \u201canode\u201d areas where metal dissolves, while the exposed parts of the metal act as \u201ccathodes.\u201d This creates a micro-galvanic cell, a small battery that drives rapid, focused corrosion right under the biofilm. Some bacteria even produce their own corrosive byproducts, like sulfuric acid, as they break down organic matter in the water. A power plant I worked with tried to skip regular biotreatment to cut costs, and within 18 months, they had to replace three large structural steel beams on their tower because of severe pitting under biofilm growth. What\u2019s worse, biofilms also trap mineral scale, adding another layer of protection that makes it hard for corrosion inhibitors to work, since they can\u2019t reach the metal surface.<\/p>\n<p>Scale, while often seen as a separate issue, is also a indirect but major cause of corrosion in open towers. When water evaporates, the dissolved minerals that don\u2019t turn to steam stay behind, their concentration increasing over time. Eventually, those minerals precipitate out of the water, forming a hard, crusty layer of scale on metal pipes, fill, and heat exchanger surfaces. That scale isn\u2019t just insulating\u2014it creates gaps between the metal and the scale where oxygen and water get trapped, again forming micro-electrochemical cells that accelerate corrosion. The scale also acts as a home for biofilms, as I mentioned earlier, so you end up with a double whammy: scale-induced corrosion plus biological growth. I recently supported a manufacturing plant where their scale had grown so thick on the heat exchanger tubes that water flow was restricted by 40%, and under the scale, each tube had at least one pinhole leak from corrosion that we had to patch.<\/p>\n<p>Galvanic corrosion is another common issue, especially when towers mix different types of metal. Many open cooling towers use a mix of materials: galvanized steel for the framework, copper for piping, stainless steel for pump components, and aluminum for fan blades. When two different metals are in contact in the presence of water (which acts as an electrolyte), a flow of electrons occurs, causing the less \u201cnoble\u201d metal (the one higher on the galvanic scale) to corrode. For example, if a galvanized steel pipe is connected directly to a copper pipe in the tower, the zinc in the galvanized steel will corrode to protect the copper, even if the copper is a more durable material. I once assisted with a hospital cooling tower where a maintenance team replaced a section of galvanized steel pipe with copper to fix a leak, but didn\u2019t add a dielectric union to separate the two metals. Within a year, the galvanized steel had corroded through right at the connection, leading to a water leak that disrupted the hospital\u2019s HVAC for a full day during a heatwave. That\u2019s a preventable mistake, but it\u2019s one we see all the time when proper material separation isn\u2019t planned for.<\/p>\n<p>Finally, operating practices also play a huge role in corrosion risk, beyond just water quality. Many facilities run their open cooling towers at very high cycles of concentration, meaning they let water evaporate and add just enough make-up water to replace losses, without properly treating the water to balance minerals and add corrosion inhibitors. Higher cycles mean higher levels of dissolved solids, which as I mentioned earlier, speed up electrochemical corrosion. Other common mistakes include not regularly cleaning the tower to remove scale and biofilm, using the wrong type of corrosion inhibitors that don\u2019t match the metal materials in the tower, or letting the water pH get too low or too high. Most metal components perform best at a pH between 7.0 and 8.5; a pH below 6.5 is acidic enough to eat away at steel and galvanized coatings, while a pH above 9.0 can cause copper to corrode rapidly. I\u2019ve also seen towers that sit unused for weeks or months at a time\u2014when the tower is idle, water can become stagnant, allowing bacteria to multiply, minerals to precipitate, and corrosion to start unchecked. A school in a northern climate shut down their tower for 5 months over winter, and when they restarted it in spring, they found 12 feet of structural steel with severe rust damage that would have cost $15,000 to repair.<\/p>\n<p>As an open cooling tower supplier, our job isn\u2019t just to provide equipment\u2014it\u2019s to help our customers understand these causes, because preventing corrosion starts long before you notice a leak or a pitted pipe. Over the years, we\u2019ve worked with hundreds of facilities to mitigate these risks: we design systems with compatible materials, include space for dielectric unions when mixing metals, provide guidance on make-up water testing, and offer regular maintenance packages that include water treatment, biofilm removal, and scale checks. We also recommend that customers test their make-up water for chloride, sulfate, and TDS at least quarterly, adjust cycles of concentration to a safe level (usually 3 to 5, depending on water quality), and schedule bi-annual tower cleanings to remove scale and biofilm.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.hnhzark.com\/uploads\/47871\/small\/adiabatic-cooling-towers0b833.jpg\"><\/p>\n<p>If you\u2019re noticing discoloration on your tower\u2019s metal components, unplanned downtime, or unexpected leaks, don\u2019t wait for corrosion to get worse. Our team has the expertise to assess your system, identify the specific corrosion risks you\u2019re facing, and recommend solutions tailored to your facility, whether that\u2019s retrofitting your existing tower, adjusting your water treatment plan, or installing a new system designed for long-term durability. Reach out to our team to schedule a site assessment and discuss your cooling tower needs.<\/p>\n<p><a href=\"https:\/\/www.hnhzark.com\/air-cooled-heat-exchanger\/\">Air Cooled Heat Exchanger<\/a> References<\/p>\n<ol>\n<li>ASHRAE Handbook\u2014HVAC Systems and Equipment, Chapter 44: Cooling Towers and Evaporative Coolers<\/li>\n<li>NACE International Standard SP0188: Standard Practice for Mitigation of Microbial Corrosion in Process Systems<\/li>\n<li>Cooling Technology Institute (CTI) Standard AWT-2021: Water Treatment for Evaporative Cooling Systems<\/li>\n<li>\u201cCorrosion in Open Recirculating Cooling Systems\u201d by G.A. George, Corrosion Science, Vol. 47, No. 12, 2005, pp. 3057-3078<\/li>\n<li>Materials Selection for Cooling Tower Components, National Association of Corrosion Engineers (NACE) International, 2019<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.hnhzark.com\/\">Hainan Haizhou Fluid Technology Co., Ltd.<\/a><br \/>As one of the most experienced open cooling tower manufacturers and suppliers in China, we also support customized service. Please feel free to wholesale bulk high quality open cooling tower in stock here from our factory. Contact us for more details.<br \/>Address: Room 3003A-877, 30th Floor, Tower A, Internet Finance Building, No. 3 Guoxing Avenue, Lantian Subdistrict, Meilan District, Haikou City, Hainan Province<br \/>E-mail: FD@jxark.com<br \/>WebSite: <a href=\"https:\/\/www.hnhzark.com\/\">https:\/\/www.hnhzark.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019ve ever stood next to an open cooling tower on an industrial plant, a school &hellip; <a title=\"What causes corrosion in open cooling towers?\" class=\"hm-read-more\" href=\"http:\/\/www.afrah-kw.com\/blog\/2026\/11\/21\/what-causes-corrosion-in-open-cooling-towers-4fca-41fcae\/\"><span class=\"screen-reader-text\">What causes corrosion in open cooling towers?<\/span>Read more<\/a><\/p>\n","protected":false},"author":295,"featured_media":3867,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3830],"class_list":["post-3867","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-open-cooling-tower-47d8-42322d"],"_links":{"self":[{"href":"http:\/\/www.afrah-kw.com\/blog\/wp-json\/wp\/v2\/posts\/3867","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.afrah-kw.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.afrah-kw.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.afrah-kw.com\/blog\/wp-json\/wp\/v2\/users\/295"}],"replies":[{"embeddable":true,"href":"http:\/\/www.afrah-kw.com\/blog\/wp-json\/wp\/v2\/comments?post=3867"}],"version-history":[{"count":0,"href":"http:\/\/www.afrah-kw.com\/blog\/wp-json\/wp\/v2\/posts\/3867\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.afrah-kw.com\/blog\/wp-json\/wp\/v2\/posts\/3867"}],"wp:attachment":[{"href":"http:\/\/www.afrah-kw.com\/blog\/wp-json\/wp\/v2\/media?parent=3867"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.afrah-kw.com\/blog\/wp-json\/wp\/v2\/categories?post=3867"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.afrah-kw.com\/blog\/wp-json\/wp\/v2\/tags?post=3867"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}